Kit Requirements & Contents

Contents & Storage

HiSeq 3000/4000 Kits

HiSeq 3000/4000 Cluster Kit

Cluster Kit Box 1, Store at -25°C to -15°C

Quantity

Reagent

Description

1

cBot Reagent Plate

PE Kit—cBot reagent plate, PE

SR Kit—cBot reagent plate, SR

1

RSB

Resuspension Buffer

1

EPX1

Enhanced Pattern Cluster Mix 1

1

EPX2

Enhanced Pattern Cluster Mix 2

1

EPX3

Enhanced Pattern Cluster Mix 3

PE Cluster Kit Box 2, Store at -25°C to -15°C

Quantity

Reagent

Description

1

HRM

HT Resynthesis Mix

1

HLM2

HT Linearization Mix 2

1

HAM

HT Amplification Mix

1

HPM

HT Amp Premix

1

HDR

HT Denaturation Mix (contains formamide)

1

HP11

Primer Mix – Read 2

1

HP14

Indexing Primer Mix

SR Cluster Kit Box 2, Store at -25°C to -15°C

Quantity

Reagent

Description

1

HRM

HT Resynthesis Mix

1

HDR

HT Denaturation Mix
(contains formamide)

1

HP12

Index 1 Primer Mix

Accessory Kit

Quantity

Accessory

Purpose

1

Flow cell gaskets (package of 4)

Replace the flow cell gaskets between runs.

1

Flow cell storage tube with storage buffer, 50 ml

Store the flow cell between clustering and sequencing.

1

Funnel bottle caps (package of 8)

Replace the caps on SBS reagent bottles before loading reagents.

The HiSeq 3000/4000 Cluster Kit also includes the following:

  • Patterned Flow Cell (Quantity 1, Store at 2°C to 8°C)
    • PE Kit—Flow Cell, PE
    • SR Kit— Flow Cell, SR  
  • cBot Manifold (Quantity 1)

HiSeq 3000/4000 SBS Kit

SBS Kit Box 1

Kit Component

Storage

Description

PW1

15°C to 30°C Wash Buffer
HB1 15°C to 30°C High Throughput SBS Buffer 1
HB2 15°C to 30°C High Throughput SBS Buffer 2

SBS Kit Box 2

Kit Component

Storage

Description

HCM

-25°C to -15°C

High Throughput Cleavage Mix

HIM

-25°C to -15°C High Throughput Incorporation Mix
HSM -25°C to -15°C High Throughput Scan Mix

SBS Kits for Dual-Indexed Sequencing

HiSeq SBS kits contain a sufficient volume of reagents for performing dual-indexed runs:

  • 300-cycle SBS kit—Up to 325 sequencing cycles
  • 150-cycle SBS kit—Up to 174 sequencing cycles
  • 50-cycle SBS kit—Up to 74 sequencing cycles. Use multiple 50-cycle kits for runs greater than the maximum number of cycles in a kit.

The following table lists the number of cycles performed for dual-indexed paired-end runs of various lengths. Run cycles comprise several sequencing cycles based on run length and 2 index reads of 8 cycles each. For dual-indexed single-read runs, 7 chemistry-only cycles are calculated in the total number of cycles.

Run Length

Run Length

Run Cycles

Total Cycles

Dual-Indexed Paired End

2 x 150

151+8+8+151

318

2 x 100

101+8+8+101

218

2 x 75

76+8+8+76

168

2 x 50

51+8+8+51

118

2 x 35

36+8+8+36

88

Dual-Indexed Single-Read

1 x 150

151+8+(7)+8

174

1 x 100

101+8+(7)+8

124

1 x 75

76+8+(7)+8

99

1 x 50

51+8+(7)+8

74

1 x 35

36+8+(7)+8

59

Safety Data Sheets